TEE BOX - STEEL BEAM JOINING DEVICE
TEE BOXES are fully calculated and tested to extreme loads.
They provide a simple alternative beam connections at 90 degrees
It is essential that the installer is familiar with the following information and instructions:

1. Use
TEE BOX with the correct beam sizes as indicated. Never exceed the safe working
loads and application as specified by a qualified structural engineer.

2. Introduce the open ended section fig.1 along the supporting beam prior to its installation.
Locate in the desired position with bolts uppermost, pinch tight.

3. The closed end section of the
TEE BOX is then introduced onto the end of the
intersecting beam with bolts uppermost, pinch tight fig 2.
Ensure beam contact with the end wall of the TEE BOX

4. The two sections of the
TEE BOX are connected together using the desired adjustment
holes with the two M20 bolts provided. These bolts must be horizontally in line and
tightened to max torque of 492Nm. fig 3.

5.
TEE BOXES are heavy. Exercise caution when lifting all heavy loads.

6.
TEE BOXES must be used for the intended application only.
Misuse or deviation from the above instructions may prove dangerous.